Negotiable
The date of payment from buyers deliver within days
Beijing
Long-term effective
2017-10-07 18:52
128
Company Profile
By certification [File Integrity]
Contact:eastups(Ms.)
Email:
Telephone:
Area:Beijing
address: No. 6 Northern Industry Road, Songshan Lake, Sci & Tech, Industry Park, Dongguan, Guangdong, China (523808)
Website: http://eastups.yhtzhangpu.com/
| MODEL | EA9010P | EA9015P | EA9020P | EA9030P | ||||
| Capacity | 10 KVA / 9 KW | 15 KVA / 13.5 KW | 20 KVA / 18 KW | 30 KVA / 27 KW | ||||
| INPUT | ||||||||
| Rated voltage | 360 V / 380 V / 400 V / 415 Vac | |||||||
| Voltage range | 277 ~ 485 Vac (no derating) 190 ~ 277 Vac (linear derating between 50% and 100% load) |
|||||||
| Rated frequency | 50 / 60 Hz (auto-sense) | |||||||
| Frequency range | 40 ~ 70 Hz | |||||||
| Power factor | ≥ 0.99 | |||||||
| Total harmonic distortion (THDI) | ≤ 5% | |||||||
| Bypass voltage range | -40% ~ +15% (settable) | |||||||
| OUTPUT | ||||||||
| Voltage | 360 V / 380 V / 400 V / 415 Vac (settable) | |||||||
| Voltage regulation | ± 1% | |||||||
| Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) | |||||||
| Waveform | Sinusoidal | |||||||
| Crest factor | 3:1 | |||||||
| Total harmonic distortion (THDV) | ≤ 2% (linear load); ≤ 5% (non-linear load) | |||||||
| Transfer time | Mains mode to battery mode: 0 ms; Inverter mode to bypass mode: 0 ms | |||||||
| Inverter overload capability | 102% ~ 125%: transfer to bypass in 10 mins; 125% ~ 150%: transfer to bypass in 1 min; > 150%: transfer to bypass in 0.5 s |
|||||||
| Bypass overload capability | 102% ~ 125%: shut down in 20 mins; 125% ~ 150%: shut down in 2 mins; > 150%: shut down in 1 s |
|||||||
| BATTERIES | ||||||||
| DC voltage | Standard model: 240 VDC; Long time model: 192 VDC (168 V / 192 V / 216 V / 240 V optional) | |||||||
| Inbuilt battery of standard model | 20 * 7 Ah | 40 * 7 Ah | 40 * 9 Ah | 60 * 9 Ah | ||||
| Recharge time | Standard model: 90% capacity restored in 4 hours; Long time model: depend on the capacity of battery |
|||||||
| SYSTEM | ||||||||
| Efficiency | ≥ 93%, ECO mode 98% | |||||||
| Display | LCD+LED | |||||||
| Alarm | Battery mode, low battery, fans fault etc. | |||||||
| Max. parallel numbers | 6 | |||||||
| EMI | IEC/EN62040-2 | |||||||
| EMS | IEC61000-4-2 (ESD) | |||||||
| IEC61000-4-3 (RS) | ||||||||
| IEC61000-4-4 (EFT) | ||||||||
| IEC61000-4-5 (surge) | ||||||||
| COMMUNICATIONS | ||||||||
| RS232 / USB / RS485 / dry contacts | Supports Windows 98 / 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10 | |||||||
| SNMP | Power management from SNMP manager and web browser | |||||||
| OTHERS | ||||||||
| Humidity | 20 ~ 90% RH @ 0-40℃ (non-condensing) | |||||||
| Noise level | ≤ 60 dB (1m) | ≤ 65 dB (1m) | ||||||
| Dimensions (W×D×H) (mm) | 350 × 655 × 732 (H) | |||||||
| 350 × 785 × 858 (S) | 350 × 785 × 1078 (S) | |||||||
| Packaged dimensions (W×D×H) (mm) | 472 × 780 × 920 (H) | |||||||
| 472 × 910 × 1050 (S) | 472 × 910 × 1260 (S) | |||||||
| Net weight (kg) | 55 (H), 110 (S) | 60 (H), 155 (S) | 61 (H), 175 (S) | 65 (H), 235 (S) | ||||
| Gross weight (kg) | 65 (H), 125 (S) | 70 (H), 170 (S) | 71 (H), 190 (S) | 75 (H), 250 (S) | ||||